Evaluation of Hydro-Electric Turbines Behavior of During Load Rejection Based on Experimental Studies

  • saman ghahghahzadeh Sama Technical and vocational training college, Islamic Azad University, Masjed-Soleiman
  • Mohammad Reza Afsharnia
Keywords: Hydro-electric turbine, load rejection, Regression

Abstract

In this paper mechanical behavior of hydro-electric turbine is investigated during load rejection test. For this purpose, several load rejection tests have been executed on unit 5 and 6 of Masjed-soleiman hydropower plant with different load before any load rejection. Then for any individual test important parameters have been measured. Finally based on numerical methods empirical formulations have been developed.

 

References

[1] R. Wamkeue , et al ," A New and Efficient Approach for Analysis of a Saturated Synchronous Generator Under the Load Rejection Test " , Electric Power Components and Systems, 34:539–563, 2006.
[2] W C Guo , J D Yang, J P Chen, Z Y Peng, Y Zhang, C C Chen , " Simulation of the transient processes of load rejection under different accident conditions in a hydroelectric generating set " , 28th IAHR symposium on Hydraulic Machinery and Systems (IAHR2016)
[3] Kaiwen Zeng, Jinyu Wen, Longpeng Ma, Shijie Cheng, En Lu and Ning Wang ," Fast Cut Back Thermal Power Plant Load Rejection and Black Start Field Test Analysis " , Energies 2014, 7, 2740-2760; doi:10.3390/en7052740
[4] Tzuu Bin Ng, G.J. Walker and J.E. Sargison ," Modeling of Transient Behavior in a Francis Turbine Power Plant " , 15th Australasian Fluid Mechanics Conference The University of Sydney, Sydney, Australia 13-17 December 2004.
[5] Working Group on Prime Mover and Energy Supply Models for System Dynamic Performance Studies, Hydraulic Turbine and Turbine Control Models for System Dynamic Performance Studies, IEEE Trans. Power Sys., 7,1992, 167–179.
[6] Rayner, P. & Ho, S., Devils Gate Power Station – Dynamic Modeling and Tasmanian Electricity Code Compliance Assessment, Hydro Electric Corp., Tasmania, Australia.Tech. Rep. GEN-112475-Report-1, 2003.
[7] Rayner, P. & Rai, P., Machine Test Guidelines (Rev. 2), Hydro Electric Corp., Tasmania, Australia. Tech. Rep. GEN-0201-TR-0002. 1999.
[8] G.J. Walker et al,"Turbine and Waterway modeling: Investigation and Development of Improved Models Stage II report", School of Engineering, University of Tasmania, Tech. Rep.. 2003.
[9] S G.J. Walker, et al, " Turbine and Waterway Modeling: Investigation and Development of Improved Models Stage I Report, School of Engineering, University of Tasmania, Tech. Rep. 2002.
[10] A. Riasi, et al, "Numerical modeling for hydraulic resonance in hydropower systems using impulse response", Journal of Hydraulic Engineering, vol. 136, no. 11, pp. 929–934, 2010.
[11] T. Kol sek, J. Duhovnik, A. Bergant, " Simulation of unsteady flow and runner rotation during shut-down of an axial water turbine", Journal of Hydraulic Research, vol. 44, no. 1, pp. 129–137, 2006.
[12] M. H. Afshar, et al "Simulation of transient flow in pipeline systems due to load rejection and load acceptance by hydroelectric power plants", International Journal of Mechanical Sciences, vol. 52, no. 1, 2010.
[13] P.Kundur, "Power System Stability and Control", Ref. Book, McGraw-Hill publications, 1994.
Published
2020-08-29
How to Cite
ghahghahzadeh, saman, & Afsharnia, M. R. (2020). Evaluation of Hydro-Electric Turbines Behavior of During Load Rejection Based on Experimental Studies. Majlesi Journal of Mechatronic Systems, 9(3). Retrieved from http://journals.iaumajlesi.ac.ir/ms/index/index.php/ms/article/view/457
Section
Articles